6KA MCB C65N-63 Miniature Circuit Breakers with Indication 1P 2Pole 3P 4P 6000A Breaking Can Be Customized DC 500V 30A 60A (1)
6KA MCB C65N-63 Miniature Circuit Breakers with Indication 1P 2Pole 3P 4P 6000A Breaking Can Be Customized DC 500V 30A 60A (2)
6KA MCB C65N-63 Miniature Circuit Breakers with Indication 1P 2Pole 3P 4P 6000A Breaking Can Be Customized DC 500V 30A 60A (3)
6KA MCB C65N-63 Miniature Circuit Breakers with Indication 1P 2Pole 3P 4P 6000A Breaking Can Be Customized DC 500V 30A 60A (4)
6KA MCB C65N-63 Miniature Circuit Breakers with Indication 1P 2Pole 3P 4P 6000A Breaking Can Be Customized DC 500V 30A 60A (5)
6KA MCB C65N-63 Miniature Circuit Breakers with Indication 1P 2Pole 3P 4P 6000A Breaking Can Be Customized DC 500V 30A 60A (6)
6KA MCB C65N-63 Miniature Circuit Breakers with Indication 1P 2Pole 3P 4P 6000A Breaking Can Be Customized DC 500V 30A 60A (7)
6KA MCB C65N-63 Miniature Circuit Breakers with Indication 1P 2Pole 3P 4P 6000A Breaking Can Be Customized DC 500V 30A 60A (8)
6KA MCB C65N-63 Miniature Circuit Breakers with Indication 1P 2Pole 3P 4P 6000A Breaking Can Be Customized DC 500V 30A 60A (9)

Sell 6KA MCB C65N-63 Miniature Circuit Breakers with Indication 1P 2Pole 3P 4P 6000A Breaking Can Be Customized DC 500V 30A 60A best price

5
40
ratings
96
sold
₱240
22% OFF
₱188 - ₱367
Ships from
Mainland China
Poles Number
1 Pole 2PCS
2 Pole
3 Pole
4 Pole
Rated Current
C10A
C16A
C20A
C25A
C32A
C40A
C50A
C63A
MX + OF DC24V
MX + OF AC220V
MX + OF AC380V
MV+MN

Product Description

TXC65-63 6KA Circuit Breaker is used for the circuit of AC 50/60Hz, rated voltage of 110V/230/400V, rated current of 1A, 2A, 3A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A OF: Auxiliary Contact; To provide auxiliary signal and control auxiliary circuit SD: Alarm Contact; To provide alarm signal when the circuit breaker breaking due to protective circuits' fault MX + OF: Shunt Release; Long-distance breaks circuit, and to control the auxiliary circuit by auxiliary contacts, and to control the auxiliary circuit b the micro-switch. MV+MN: overvoltage and undervoltage release; To make the circuit breaker tripping and protect the line when the 230V rated supply voltage rises to 270±5% or falls at 170±5%V ------ Compared 1P: 18MM Width | 1 Pole 2P: 36MM Width | 2 Pole 3P: 54MM Width | 3 Pole 4P: 72MM Width | 4 Pole TXL7 10KA Breaking capacity > TXC65 6KA Breaking capacity > DZ47 4KA Breaking capacity ------ Specifications Model:TXC65 Rated Operating Voltage: AC 110V 230V 400V Poles: 1P | 2P | 3P | 4P Rated Current: 6A 10A 16A 20A 25A 32A 40A 50A 63A Working Frequency: 50/60Hz breaking capacity: 6 kA Trip Curve: C Mechanical Life: 20,000 times Electrical Life: 10,000 times Installation Method: 35MM DIN Rail Standard: IEC60898-1 / GB10963.1. operating temperature 23°F(-5℃) ~ 104°F(40℃) Operating Altitude: 2000 Meter ------ Features 1.High rated short circuit breaking capacity: TXC65 is 6KA Miniature Circuit Breaker. 2.OF auxiliary contact, SD alarm contact, MX + OF shunt release, MV over-voltage release, MN undervoltage release, MV + MN over-voltage release ------ Package 1x.TXC65-63 Circuit Breaker

Product Specifications

Country of OriginChina