Risin 1P 2P 4P Solar DC Miniature Circuit Breaker Din Rail 500V 1000V DC MCB C Curve 10A to 63A 80A (1)
Risin 1P 2P 4P Solar DC Miniature Circuit Breaker Din Rail 500V 1000V DC MCB C Curve 10A to 63A 80A (2)
Risin 1P 2P 4P Solar DC Miniature Circuit Breaker Din Rail 500V 1000V DC MCB C Curve 10A to 63A 80A (3)
Risin 1P 2P 4P Solar DC Miniature Circuit Breaker Din Rail 500V 1000V DC MCB C Curve 10A to 63A 80A (4)
Risin 1P 2P 4P Solar DC Miniature Circuit Breaker Din Rail 500V 1000V DC MCB C Curve 10A to 63A 80A (5)
Risin 1P 2P 4P Solar DC Miniature Circuit Breaker Din Rail 500V 1000V DC MCB C Curve 10A to 63A 80A (6)
Risin 1P 2P 4P Solar DC Miniature Circuit Breaker Din Rail 500V 1000V DC MCB C Curve 10A to 63A 80A (7)
Risin 1P 2P 4P Solar DC Miniature Circuit Breaker Din Rail 500V 1000V DC MCB C Curve 10A to 63A 80A (8)
Risin 1P 2P 4P Solar DC Miniature Circuit Breaker Din Rail 500V 1000V DC MCB C Curve 10A to 63A 80A (9)

Sell Risin 1P 2P 4P Solar DC Miniature Circuit Breaker Din Rail 500V 1000V DC MCB C Curve 10A to 63A 80A best price

0
ratings
₱1,403 - ₱6,046
Ships from
Santa Cruz, Metro Manila
Color
2P 550V
1P 250V
4P 1000V
Size
63A
100A
50A
25A
125A
32A
16A
40A
80A
10A
6A
20A

Product Description

⚡ Description : 1Pole 2Pole 4Pole 550V 1000V DC Solar Circuit Breaker Din Rail DC Circuit Breaker C Curve are designed to provide overcurrent protection within appliances or electrical equipment, where a branch circuit protection is already protection or not required. Devices are designed for direct current (DC) control circuit applications in Solar PV Systems. ⚡ Technical Data : Model Name: TOMC7-DC63 Pole No. : 1P, 2P, 4P Rated Voltage : 1P=250VDC, 2P=550VDC, 4P=1000VDC Rated Current : 6A,10A,16A,20A,25A,32A,40A,50A,63A,80A,100A,125A Breaking Capacity : 6KA Curve Type : C Standard : IEC60947, IEC60898 Mounting Support : DIN rail 35mm Dimension : 1P : 18*75*85 mm 2P : 36*75*85 mm 4P : 54*75*85 mm ⚡ Advantages : · DC Circuit Breakeris for non-professional operation by those untrained, and no maintenance is required. · Satisfying conditions and applications as mentioned above,MCB with “ON-OFF” indicating device is considered suitable for isolation function. · Particular devices such as surge protective devices,surge arrester etc are recommended to install at upstream line to MCB as precaution against potential surge voltage and current occurring at its power input side. · Appropriate tripping curve being chosen and properly installed, MCB trips and switches off its protected circuit in case of fault, and thus provides protection against electric shock. · Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity. · Protection against both overload and short circuit · Contact position indication · Applicable to terminal and pin/fork type Busbar connection · Easy mounting onto 35mm DIN rail ⚡ What's in the package : 1pcs of DC Circuit Breaker 1P/2P/4P 🚩🚩 Why Choosing Risin ? · 12 Years experience in solar factory · 30 Minutes to reply after received message · 25 Years Warranty for MC4 Connector, PV Cable · No compromise on quality

From the same shop

Related items

You may also like