✜Solar Energy PV MCB DC 1000V Miniature Circuit Breakers 2P 60A 500V Photovoltaic Power Generation S (1)
✜Solar Energy PV MCB DC 1000V Miniature Circuit Breakers 2P 60A 500V Photovoltaic Power Generation S (2)
✜Solar Energy PV MCB DC 1000V Miniature Circuit Breakers 2P 60A 500V Photovoltaic Power Generation S (3)
✜Solar Energy PV MCB DC 1000V Miniature Circuit Breakers 2P 60A 500V Photovoltaic Power Generation S (4)
✜Solar Energy PV MCB DC 1000V Miniature Circuit Breakers 2P 60A 500V Photovoltaic Power Generation S (5)
✜Solar Energy PV MCB DC 1000V Miniature Circuit Breakers 2P 60A 500V Photovoltaic Power Generation S (6)
✜Solar Energy PV MCB DC 1000V Miniature Circuit Breakers 2P 60A 500V Photovoltaic Power Generation S (7)
✜Solar Energy PV MCB DC 1000V Miniature Circuit Breakers 2P 60A 500V Photovoltaic Power Generation S (8)
✜Solar Energy PV MCB DC 1000V Miniature Circuit Breakers 2P 60A 500V Photovoltaic Power Generation S (9)

Sell ✜Solar Energy PV MCB DC 1000V Miniature Circuit Breakers 2P 60A 500V Photovoltaic Power Generation S best price

0
ratings
₱686 - ₱2,126
Ships from
Dapitan City, Zamboanga Del Norte
Variation
4P DC1000V
2P DC1000V
2P DC500V
1P DC250V 2Pcs
Size
25A
50A
16A
32A
100A
10A
125A
6A
63A
20A
80A
40A

Product Description

This product is mainly used for the overload and short circuit protection of DC120V-DC1000V photovoltaic systems. ------ Compared 1P: Max for DC250V 4KA breaking capacity | 18MM Width | 1 Pole DC circuit breaker | Only protect the + or - pole 2P: Max for DC500V 4KA breaking capacity or DC1000V 2KA breaking capacity | 36MM Width | 2 Pole DC circuit breaker | Protect For - And + Pole 4P: DC1000V 4KA breaking capacity | 36MM Width | 4 Pole DC circuit breaker | Protect For - And + Pole 4P VS 2P superposition of 2P circuit breakers increases the short-circuit breaking capacity for better protection, greater the voltage, greater the short-circuit current. It is recommended to use a 4P circuit breaker for DC1000V ------ Specifications Model: DZ47Z Rated Operating Voltage : DC120V-DC1000V Poles: 1P 2P 4P Rated Current: 6A 10A 16A 20A 25A 32A 40A 50A 63A 80A 125A Working Frequency: 50/60Hz breaking capacity: 4 kA Ics=Icu Trip Curve: C Mechanical Life: 10,000 times Electrical Life: 5,000 times Installation Method: 35MM DIN Rail Standard: IEC60898 / GB10936 Operating Temperature: -30°C to +70°C Operating Altitude: 2000 Meter ------ Features It has the functions of photovoltaic systems protection,overload protection, ------ Package 1xDZ47Z Circuit Breaker

From the same shop

Related items

You may also like