【spot goods】 ✠✾▬Type A AC CLASS Rcbo 110V 220V RCCB 10A 20a 40A 50A 63A 30mA Residual Current Circu (1)
【spot goods】 ✠✾▬Type A AC CLASS Rcbo 110V 220V RCCB 10A 20a 40A 50A 63A 30mA Residual Current Circu (2)
【spot goods】 ✠✾▬Type A AC CLASS Rcbo 110V 220V RCCB 10A 20a 40A 50A 63A 30mA Residual Current Circu (3)
【spot goods】 ✠✾▬Type A AC CLASS Rcbo 110V 220V RCCB 10A 20a 40A 50A 63A 30mA Residual Current Circu (4)
【spot goods】 ✠✾▬Type A AC CLASS Rcbo 110V 220V RCCB 10A 20a 40A 50A 63A 30mA Residual Current Circu (5)
【spot goods】 ✠✾▬Type A AC CLASS Rcbo 110V 220V RCCB 10A 20a 40A 50A 63A 30mA Residual Current Circu (6)
【spot goods】 ✠✾▬Type A AC CLASS Rcbo 110V 220V RCCB 10A 20a 40A 50A 63A 30mA Residual Current Circu (7)

Sell 【spot goods】 ✠✾▬Type A AC CLASS Rcbo 110V 220V RCCB 10A 20a 40A 50A 63A 30mA Residual Current Circu best price

0
ratings
₱687 - ₱1,184
Ships from
Binondo, Metro Manila
Variation
A TYPE 220V 30mA
AC TYPE 110V 30mA
A TYPE 110V 30mA
AC TYPE 220V 30mA
Size
10A
63A
16A
25A
32A
20A
50A
40A

Product Description

TXDB1L-63 (phase line + neutral line+ leakage + overvoltage) protection circuit breaker is suitable for the single-phase residential circuit of 50Hz / 60Hz, rated voltage of 230V, rated current of 63A, to protect leakage, and protect overload and short-circuit of the civil electrical circuit. ------ Compared AC TYPE 220V 30mA: For AC 220V~240V Voltage | AC leakage protection | AC overload short circuit protection A TYPE 220V 30mA: For AC 220V~240V Voltage | AC leakage protection + Pulsating DC Leakage Protection | AC overload short circuit protection AC TYPE 110V 30mA: For AC 100V~120V Voltage | AC leakage protection | AC overload short circuit protection A TYPE 110V 30mA: For AC 100V~120V Voltage | AC leakage protection + Pulsating DC Leakage Protection | AC overload short circuit protection Pulsating DC leakage protection=AC to DC output Such as DC leakage of battery car charging, Power Supply,telephone charging ------ Specifications Model: TXDB1L-63 Rated Operating Voltage: 110V/220V AC Poles: 1P+N Rated Current: 10A 16A 20A 25A 32A 40A 50A 63A Working Frequency: 50/60Hz breaking capacity: 4.5 kA Trip Curve: C Rated Residual Operating Current: 30mA Mechanical Life: 20,000 times Electrical Life: 10,000 times Installation Method: in distribution box, power distribution cabinet or box with standard rail (TH35-7.5). Standard: IEC61009-1 / GB16917.1 operating temperature -5℃~+40℃,and the daily average temperature does not exceed +35℃ Operating Altitude: <2000 Meter ------ Features 1.It has short-circuit protection, overload protection, leakage protection. ------ Package 1x TXDB1L-63 Circuit Breaker

From the same shop

Related items

You may also like