Schneider Acti9 IEC 2P 20A C DIN-Rail Type Miniature Circuit Breaker 230/400V 10kAIC (A9F74220) (1)
Schneider Acti9 IEC 2P 20A C DIN-Rail Type Miniature Circuit Breaker 230/400V 10kAIC (A9F74220) (2)
Schneider Acti9 IEC 2P 20A C DIN-Rail Type Miniature Circuit Breaker 230/400V 10kAIC (A9F74220) (3)
Schneider Acti9 IEC 2P 20A C DIN-Rail Type Miniature Circuit Breaker 230/400V 10kAIC (A9F74220) (4)

Sell Schneider Acti9 IEC 2P 20A C DIN-Rail Type Miniature Circuit Breaker 230/400V 10kAIC (A9F74220) best price

0
ratings
1
sold
โ‚ฑ816
Brand
SCHNEIDER
Ships from
Pasay City, Metro Manila

Product Description

๐—ข๐—™๐—™๐—œ๐—–๐—œ๐—”๐—Ÿ ๐—ฆ๐—ง๐—ข๐—ฅ๐—˜ ๐—ฆ๐—ฃ๐—˜๐—–๐—œ๐—™๐—œ๐—–๐—”๐—ง๐—œ๐—ข๐—ก๐—ฆ ๐— ๐—ฎ๐—ถ๐—ป โ€ข Device Application: Distribution โ€ข Range: Acti 9 โ€ข Product Name: Acti 9 iC60 โ€ข Product or Component Type: Miniature Circuit-Breaker โ€ข Device Short Name: IC60N โ€ข Poles Description: 2P โ€ข Number of Protected Poles: 2 โ€ข [In] Rated Current: 16 A โ€ข Network Type โ€ข AC โ€ข DC โ€ข Trip Unit Technology: Thermal-magnetic โ€ข Curve Code: C โ€ข Breaking Capacity โ€ข 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 โ€ข 36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 โ€ข 10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 โ€ข 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 โ€ข 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 โ€ข 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 โ€ข 36 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 โ€ข Utilisation Category โ€ข Category A conforming to EN 60947-2 โ€ข Category A conforming to IEC 60947-2 โ€ข Suitability for Isolation โ€ข Yes conforming to EN 60898-1 โ€ข Yes conforming to EN 60947-2 โ€ข Yes conforming to IEC 60898-1 โ€ข Yes conforming to IEC 60947-2 โ€ข Standards โ€ข IEC 60898-1 โ€ข EN 60898-1 โ€ข IEC 60947-2 โ€ข EN 60947-2 ๐—–๐—ผ๐—บ๐—ฝ๐—น๐—ฒ๐—บ๐—ฒ๐—ป๐˜๐—ฎ๐—ฟ๐˜† โ€ข Network frequency: 50/60 Hz โ€ข Magnetic Tripping Limit: 8 x In +/- 20 % โ€ข [Ics] Rated Service Breaking Capacity โ€ข 15 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz โ€ข 7.5 kA 75 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz โ€ข 4.5 kA 75 % conforming to EN 60947-2 - 440 V AC 50/60 Hz โ€ข 15 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz โ€ข 7.5 kA 75 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz โ€ข 4.5 kA 75 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz โ€ข 27 kA 75 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz โ€ข 27 kA 75 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz โ€ข 6000 A 100 % conforming to EN 60898-1 - 400 V AC 50/60 Hz โ€ข 6000 A 100 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz โ€ข 10 kA 100 % conforming to IEC 60947-2 - 72...125 V DC โ€ข 10 kA 100 % conforming to EN 60947-2 - 72...125 V DC โ€ข Limitation class โ€ข 3 conforming to EN 60898-1 โ€ข 3 conforming to IEC 60898-1 โ€ข [Ui] Rated Insulation Voltage โ€ข 500 V AC 50/60 Hz conforming to EN 60947-2 โ€ข 500 V AC 50/60 Hz conforming to IEC 60947-2 โ€ข [Uimp] Rated Impulse withstand Voltage โ€ข 6 kV conforming to EN 60947-2 โ€ข 6 kV conforming to IEC 60947-2 โ€ข Contact Position Indicator: Yes โ€ข Control Type: Toggle โ€ข Local Signalling: Trip Indicator โ€ข Mounting Mode: Fixed โ€ข Mounting Support: DIN Rail โ€ข Comb Busbar and Distribution Block Compatibility: Top or bottom: YES โ€ข 9 mm Pitches: 4 โ€ข Height: 85 mm โ€ข Width: 36 mm โ€ข Depth: 78.5 mm โ€ข Net Weight: 0.25 kg โ€ข Colour: White โ€ข Mechanical Durability: 20000 cycles โ€ข Electrical Durability: 10000 cycles โ€ข Connections - Terminals โ€ข Single terminal (top or bottom) 1โ€ฆ25 mmยฒ rigid โ€ข Single terminal (top or bottom) 1โ€ฆ16 mmยฒ flexible โ€ข Wire Stripping Length: 14 mm for top or bottom connection โ€ข Tightening Torque: 2 N.m top or bottom โ€ข Earth-leakage Protection: Separate block ๐—˜๐—ป๐˜ƒ๐—ถ๐—ฟ๐—ผ๐—ป๐—บ๐—ฒ๐—ป๐˜ โ€ข IP Degree of Protection โ€ข IP20 conforming to IEC 60529 โ€ข IP20 conforming to EN 60529 โ€ข Pollution Degree โ€ข 3 conforming to EN 60947-2 โ€ข 3 conforming to IEC 60947-2 โ€ข Overvoltage Category: IV โ€ข Tropicalisation: 2 conforming to IEC 60068-1 โ€ข Relative Humidity: 95 % at 55 ยฐC โ€ข Operating Altitude: 0...2000 m โ€ข Ambient air temperature for operation: -35โ€ฆ70 ยฐC โ€ข Ambient air temperature for storage: -40โ€ฆ85 ยฐC ๐—ข๐—ณ๐—ณ๐—ฒ๐—ฟ ๐—ฆ๐˜‚๐˜€๐˜๐—ฎ๐—ถ๐—ป๐—ฎ๐—ฏ๐—ถ๐—น๐—ถ๐˜๐˜† โ€ข Sustainable offer status: Green Premium product โ€ข REACh Regulation: REACh Declaration โ€ข REACh free of SVHC: Yes โ€ข EU RoHS Directive โ€ข Compliant โ€ข EU RoHS Declaration โ€ข Mercury free: Yes โ€ข RoHS exemption information: Yes โ€ข China RoHS Regulation โ€ข China RoHS declaration โ€ข Product out of China RoHS scope. Substance declaration for your information โ€ข Environmental Disclosure: Product Environmental Profile โ€ข WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins โ€ข Halogen content performance: Halogen free product ๐——๐—œ๐— ๐—˜๐—ก๐—ฆ๐—œ๐—ข๐—ก๐—ฆ ๐—ฃ๐—ฎ๐—ฐ๐—ธ๐—ถ๐—ป๐—ด ๐—จ๐—ป๐—ถ๐˜๐˜€ โ€ข Package 1 Weight: 0.216 kg โ€ข Package 1 Height: 0.700 dm โ€ข Package 1 Width: 0.350 dm โ€ข Package 1 Length: 0.950 dm ------------------------------------------------------------------------------------------------------------------------------------------------------------------ ๐—ช๐—”๐—ฅ๐—ฅ๐—”๐—ก๐—ง๐—ฌ โ€ข 18-Months Local Manufacturer's Warranty โ€ข All shipping fees shall be shouldered by the buyer. โ€ข Kindly send us a message on how to claim the warranty. #Schneider #Acti9 #officialstore #Schneiderelectrics #MiniatureCircuitbreaker #shopeemall #brandnew #original #legit #legitseller

From the same shop

Related items

You may also like