Electrical Safety∈✚IC60N - miniature circuit breaker - 1P - C curve by Schneider Electric (1)
Electrical Safety∈✚IC60N - miniature circuit breaker - 1P - C curve by Schneider Electric (2)
Electrical Safety∈✚IC60N - miniature circuit breaker - 1P - C curve by Schneider Electric (3)
Electrical Safety∈✚IC60N - miniature circuit breaker - 1P - C curve by Schneider Electric (4)
Electrical Safety∈✚IC60N - miniature circuit breaker - 1P - C curve by Schneider Electric (5)
Electrical Safety∈✚IC60N - miniature circuit breaker - 1P - C curve by Schneider Electric (6)
Electrical Safety∈✚IC60N - miniature circuit breaker - 1P - C curve by Schneider Electric (7)

Sell Electrical Safety∈✚IC60N - miniature circuit breaker - 1P - C curve by Schneider Electric best price

0
ratings
₱1,176
50% OFF
₱588 - ₱797
Ships from
Ermita, Metro Manila
Variation
A9F74106- 6 AMPERE
A9F74110- 10 AMPERE
A9F74125- 25 AMPERE
A9F74150- 50 AMPERE
A9F74102- 2 AMPERE
A9F74103- 3 AMPERE
A9F74104- 4 AMPERE
A9F74116- 16 AMPERE
A9F74120- 20 AMPERE
A9F74132- 32 AMPERE
A9F74140- 40 AMPERE
A9F74163- 63 AMPERE

Product Description

This Acti 9 iC60N is a low voltage miniature circuit breaker (MCB). It is a 1P circuit-breaker with 1 protected pole VisiTrip™ minimizes downtime and reduces repair times. Identify faults in one glance and you will easily see the operating status of your network. VisiTrip™ indicates only the faulty outgoer, allowing fast diagnosis, resolution, and reclosing loads for easier building management and reduced downtime. -VisiSafe™ design guarantees the downstream circuit is always safe regardless of overvoltage conditions, wear, or operation experience, even in most demanding environment. -Class-2 insulation: ensures continuous protection for both operators and unqualified persons. -Communication ready, with Acti9 Smartlink. It has one-click, prefabricated wiring for fast, easy communication between your distribution panel and any existing facility management system. Poles description: 1P Number of protected poles: 1 [In] rated current: 2 A - 63A Network type     DC AC Trip unit technology: Thermal-magnetic Curve code: C Breaking capacity:     6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 50 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 Utilisation category: Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 Suitability for isolation:     Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 Standards     EN 60898-1 IEC 60898-1 EN 60947-2 IEC 60947-2 Quality labels: NF