✔☁Driver Board/1pc TN 90/2pc TN 90/2pcs TN 90 Pointer VU Meter + 1pcs Driver Board Pre stage DB W/Ba (1)
✔☁Driver Board/1pc TN 90/2pc TN 90/2pcs TN 90 Pointer VU Meter + 1pcs Driver Board Pre stage DB W/Ba (2)
✔☁Driver Board/1pc TN 90/2pc TN 90/2pcs TN 90 Pointer VU Meter + 1pcs Driver Board Pre stage DB W/Ba (3)
✔☁Driver Board/1pc TN 90/2pc TN 90/2pcs TN 90 Pointer VU Meter + 1pcs Driver Board Pre stage DB W/Ba (4)

Sell ✔☁Driver Board/1pc TN 90/2pc TN 90/2pcs TN 90 Pointer VU Meter + 1pcs Driver Board Pre stage DB W/Ba best price

0
ratings
₱2,228
22% OFF
₱1,738 - ₱4,536
Ships from
Caloocan City, Metro Manila
Variation
2 with 1
2pc TN-90
1pc TN-90
1pcs Driver Board

Product Description

Driver Board/1pc TN-90/2pc TN-90/2pcs TN-90 Pointer VU Meter + 1pcs Driver Board Pre-stage DB W/Backlight Power Amplifier Board You have four options: ● 1pcs Driver Board for VU Meter ● 1pcs TN-90 VU Meter ● 2pcs TN-90 VU Meters ● 2 with 1: 2pcs TN-90 VU Meters + 1pcs Driver Board for VU Meter Parameters: ● Pointer material: zinc white copper ● Pointer color: orange ● Pointer swing direction: from left to right ● Pointer length: 44 ± 1mm from the center axis to the needle end ● Pointer width: 0.45 ± 0.05 mm ● Electric meter use direction: Vertical Electrical performance: ● Standard test conditions: temperature 20 ℃, humidity 70%, if there is no difference in the test results, the test can also be performed at normal temperature and humidity. ● Current sensitivity: the pointer is in the zero scale to the maximum scale (full scale position) Sensitivity 960uA ± 8%. ● Internal impedance: 650 Ω ± 10%. ● Insulation resistance: 500V DC plus 50M ohm or more for the outer box of the meter and the electrical circuit. The insulation resistance of the meter housing and the electrical circuit is tested by 500V DC voltage. ● Zero position: the standard position of the meter is used, and the point where the front of the pointer and the center of the zero scale are unified is the reference pointer and the zero scale overlap. The tolerance is ± 1mm. ● Balance: The allowable error range of the meter when the standard position is tilted 90 degrees forward and backward is ± 1mm. ● The pointer sticks: When the full-scale current triples the overcurrent in an instant and slowly reduces to the current sensitivity reading of 1/2, the pointer will return to the scale of 1/3 of the scale. ● Friction: When the current is added to the meter and slowly increased or decreased to a certain value, the error range of the indicated point is ± 1mm. ● Braking: instantly add 2/3 of the current value of the scale plate, within one second from the start to the position indicated by the pointer verticalˈvərtikəl. Special Test: ● Overload test Input ten times the full-scale current every five seconds, and this action is repeated nine times. Each time is 0.5 seconds, and the test remains normal. ● Vibration test: After the meter is packaged, vibration is carried out on the vibration plate 1,000 times per minute up and down 4mm, 10 minutes per direction. After this test, 7-14 items remain normal. ● Impact test: After the packaging of the electric meter, it is dropped from a height of 30 cm on a 3cm thick wooden board. The X.Y.Z. three-direction test is normal. ● Reliability test: After 100,000 times of current input to the calibration point, the current sensitivity limit is still within the standard Environmental impact test Temperature 50 ℃, humidity 85%, lasts 100 hours, after this test remains normal. ● Terminal pull test The terminal must withstand a 1 kg pull for 60 seconds without being affected. The Others: ● Operating temperature limit: -10 ℃ to + 60

From the same shop

Related items

You may also like