DPNL 1P+N RCBO C40A Residual Current Circuit Breaker WIth Overload protection 63A 32A 16A 36MM RCCB DZ267LE TXDB1L (1)
DPNL 1P+N RCBO C40A Residual Current Circuit Breaker WIth Overload protection 63A 32A 16A 36MM RCCB DZ267LE TXDB1L (2)
DPNL 1P+N RCBO C40A Residual Current Circuit Breaker WIth Overload protection 63A 32A 16A 36MM RCCB DZ267LE TXDB1L (3)
DPNL 1P+N RCBO C40A Residual Current Circuit Breaker WIth Overload protection 63A 32A 16A 36MM RCCB DZ267LE TXDB1L (4)
DPNL 1P+N RCBO C40A Residual Current Circuit Breaker WIth Overload protection 63A 32A 16A 36MM RCCB DZ267LE TXDB1L (5)
DPNL 1P+N RCBO C40A Residual Current Circuit Breaker WIth Overload protection 63A 32A 16A 36MM RCCB DZ267LE TXDB1L (6)

Sell DPNL 1P+N RCBO C40A Residual Current Circuit Breaker WIth Overload protection 63A 32A 16A 36MM RCCB DZ267LE TXDB1L best price

4.9
196
ratings
469
sold
₱509
45% OFF
₱280 - ₱585
Ships from
Mainland China
Poles
A TYPE 220V 30MA
AC TYPE 220V 30MA
AC Type AC110V 30mA
A Type AC110V 30mA
Rated Current
16A
50A
10A
40A
32A
25A
20A
63A

Product Description

TXDB1L-63 Residual Current Circuit Breaker improved from by DZ30LE, the internal circuit board adopts integrated circuit, the performance is more superior and reliable! TXDB1L-63 (DPN Vigi) (phase line + neutral line+ leakage + overvoltage) protection circuit breaker is suitable for the single-phase residential circuit of 50Hz / 60Hz, rated voltage of 230V, rated current of 63A, to protect leakage, and protect overload and short-circuit of the civil electrical circuit. The earth leakage switch can also infrequently switch on or off electrical equipment and lighting lines under normal circumstances, especially for industrial and commercial lighting distribution system. The earth leakage switch mcb has a small size, high breaking capacity; null line and live line are cut off at the same time, and in the case of live line reversed, the electric leakage circuit breaker still able to protect against leakage. The filter in the electronic leakage over-voltage protection can prevent the misoperation tripping caused by instantaneous voltage (lighting, line interference of other equipment) and instantaneous current (such as capacitive load line). the electric leakage circuit breaker meets standards of GB16917.1 and others. CLASS A=DC+AC LEAKAGE PROTECTION CLASS AC=AC LEAKAGE PROTECTION The main difference between Type A leakage protector and AC type leakage protector is: The AC type only protects AC leakage, and cannot act DC pulsation leakage, so it cannot protect DC pulsation leakage; but A type not only protects AC leakage protection, it also protects DC pulsation leakage. Therefore, the A type is more comprehensive and safer than the AC type for leakage protection. since so many electrical accident caused by DC pulsation leakage have occurred from time to time such as human body electric shocks, electrical equipment damage, electrical fires, etc. ,causing casualties and property losses that should not have occurred, it have attracted the attention of government departments and industry professionals. So it is imperative to vigorously promote the use of A-type leakage protectors. ■ Rated current: 6,10,16,20,25,32,40,50,63 A ■ Rated operating voltage: 230 / 400V AC ■ Rated insulation voltage: 500V ■ Rated residual operated current: 30mA ■ Breaking capacity: 4.5kA ■ Trip indicator: TXDB1L electric leakage circuit breaker has residual current operated trip indicator window, when leakage fault trip, the window changes from colorless to red ■ Mechanical life: 8000 times ■ Electrical life: 2000 times ■ Wiring: 6 ~ 63A, can be connected to wires of 25mm ⊃2; and below ■ Standard: IEC61009-1 / GB16917.1 ■ Certification: CCC, Cb ■ Tripping characteristics: C-type curve, protection of conventional load and distribution cables, instantaneous trip range (5 ~ 10) In

From the same shop

Related items

You may also like