6-30V Relay Module Switch Trigger Time Delay Circuit Timer Cycle Adjustable 828 Promotion (1)
6-30V Relay Module Switch Trigger Time Delay Circuit Timer Cycle Adjustable 828 Promotion (2)
6-30V Relay Module Switch Trigger Time Delay Circuit Timer Cycle Adjustable 828 Promotion (3)
6-30V Relay Module Switch Trigger Time Delay Circuit Timer Cycle Adjustable 828 Promotion (4)
6-30V Relay Module Switch Trigger Time Delay Circuit Timer Cycle Adjustable 828 Promotion (5)
6-30V Relay Module Switch Trigger Time Delay Circuit Timer Cycle Adjustable 828 Promotion (6)
6-30V Relay Module Switch Trigger Time Delay Circuit Timer Cycle Adjustable 828 Promotion (7)
6-30V Relay Module Switch Trigger Time Delay Circuit Timer Cycle Adjustable 828 Promotion (8)
6-30V Relay Module Switch Trigger Time Delay Circuit Timer Cycle Adjustable 828 Promotion (9)

Sell 6-30V Relay Module Switch Trigger Time Delay Circuit Timer Cycle Adjustable 828 Promotion best price

4.9
122
ratings
576
sold
₱126
Ships from
Mainland China

Product Description

Product introduction: 1. Operating voltage: 6--30V 2. Trigger Signal Source: High Level Trigger (3.0 V-24 V), signal ground and system ground are not common, which can increase anti-interference abilit system (short circuit can also connect with a ground common) 3. Output Capacity: can control no more than DC 30V 5A AC or 220 V devices 5A 4. Optocoupler Isolation: improve the anti-interference ability, after the parameter setting, it will memory forever Warning: Relay contact is passive and electricity production; 1 channel has the control function on / off Operation mode: P1: After triggered signal, power relay on time OP, then turn off; within the OP period following operation: 1) P1.1: signal being triggered again is not effective 2) P1.2: signal being triggered again, start time again 3) P1.3: signal being triggered again, reset; disconnect relay, stop timing P2: giving the trigger signal, the time after shutdown relay CL power relay OP time; then timing, turn off the relay P3.1: give the trigger signal after the power relay on time OP, CL shutdown time relay; then operating cycle above cycle gaive signal again, shutdown relay stop timing; cycle times (LOP) can be set P3.2: after connecting. no need to trigger signal, power relay on time OP, CL shutdown time relay; then the operating cycle above timea cycle (LOP) can be set Q4: keeping the function of the signal; if there is no trigger signal, the time will be canceled, relay stay connected; when the signal disappears, timing OP turn off the relay; over time, if no signal again, the time is cleared Time interval: 0.1 s (minimum) ~ 999 min (maximum) continuously adjustable how to choose the time interval: in the selection of parameter set interface mode, and press the STOP button to select the time xxx. if the decimal point is in some place, the time interval is s-1 999 s xx. x is decimal place is ten, the time interval is 0.1 s 99.9 s- x. x. x is the decimal point are all on, the time interval is 1 min-999 min parameter Introduction: OP power over time, turn off time CL, LOP cycle times (1-999 times, "---" is unlimited cycle) How to set the parameter: 1. First make sure relay operation mode 2. According to the operaiting relay mode, the main interface (power module will flash current operating mode; standard mode P1.1, then come intot main interface); long press SET key two seconds and then looen enter selection interface mode; by pressing UP, DOWN key to choose the mode setting (P1.1 ~ P4) 3. After selecting the mode, press short SET to set the corresponding parameter, then the parameter you want to set will flash (OP power in time; CL power off time; LOP cycle times, "---" is unlimited cycle ); by UP, DOWN to set the parameter value, support long press

From the same shop

Related items

You may also like